Technical Specification Capacity (Kg) 1 & 2 Extinguishing Media MAP 90 UL Listed/Mechanical Foam Pressure No pressure Technology Pyrotechnics (PESO Licensed) Coverage 1Kg- 6ft x 6ft, 2Kg - 10ft x 10ft Application: Class A Fire: Wood, Textiles, Paper, Clothes, Cotton Mill, Jute Mill etc. Class B Fire : Petroleum, Oil, Paint, Varnish, Solvent, Aviation Fuel, Flammable and Volatile Liquids etc. Class C Fire : Flammable Gasses, Industrial Gasses etc. As well as Electrically Started Fires.
Technical Specification Capacity (Kg) 500 gms, 1, 2, 4, 6 & 9 Kg Anti-Corrosive Inhibitor Epoxy Polyester Powder Coating PressureConforming IS Code 15683 Type of Extinguisher Constant Pressure Type of Extinguishing Media Dry Powder IS 14609(MAP90, MAP50) Expellant Pressurized with N2 Gas / Gas Cartridge Minimum Effective Discharge (%) 85 Minimum jet Length (mtrs.) More than 2 Discharge Time (Sec.) More than 8 Hydraulic Test Pressure (Kgf/cm2) 35 Operating Position Upright Charged Pressure (Kgf/cm2) 15 Operating Temperature Range ° (176) {C} (-)10 to (+)55 Operating Valve Squeeze Grip Type with Discharge Hose & Nozzle Application: Class A Fire : Wood, Textiles, Paper, Clothes, Cotton Mill, Jute Mill etc. Class B Fire : Petroleum, Oil, Paint, Varnish, Solvent, Aviation Fuel, Flammable and Volatile Liquids etc. Class C Fire : Flammable Gasses, Industrial Gasses etc. As well as Electrically Started Fires.
Technical Specification Capacity (Kg) 2, 3 & 4.5 Conforming IS Code 15683 Filling Ratio 0.667 Type of Extinguisher CO2 Type Type of Extinguishing Media CO2 Gas Minimum Effective Discharge (%) 95 Minimum Discharge Time (Sec.) More than 8 Minimum Throw (mtrs.) 1 Operating Position Upright Operating Value (IS:3324) Wheel/Squeeze Grip Type Operating Temperature Range ° (176) {C} (-)30 to (+)55 Application: Class B Fire: Petroleum, Oil, Paint, Varnish, Solvent, Aviation Fuel, Flammable and Volatile Liquids etc. Class C Fire : Flammable Gasses, Industrial Gasses etc. As well as Electrically Started Fires.
Technical Specification Capacity (Ltr) 9 Anti-Corrosive Inhibitor Epoxy Polyester Powder Coating Conforming IS Code 15683 Type of Extinguisher Constant Pressure Type of Extinguishing Media AFFF IS 4989 Expellant Pressurized with N2 Gas / Gas cartridge Minimum Effective Discharge (%) 95 Minimum Jet Length (mtrs.) More than 2 Discharge Time (Sec.) More than 13 Hydraulic Test Pressure (Kgf/cm2) 35 Operating Position Upright Charged Pressure (Kgf/cm2) 15 Operating Temperature Range ° (176) {C} (+)5 to (+)55 Operating Valve Squeeze Grip Type with Discharge Hose & Nozzle Application: Class A Fire : Wood, Textiles, Paper, Clothes, Cotton Mill, Jute Mill etc Class B Fire : Petroleum, Oil, Paint, Varnish, Solvent, Aviation Fuel, Flammable and Volatile Liquids etc. Note: Do not use on energized Electrical Equipment fires.
Technical Specification Capacity (Kg) 2, 5, & 10 Extinguishing Media ABC Dry Powder/ Clean Agent/ Powder Minimum Effective Discharge (%) 95 Testing Pressure (kgf/cm2) 35 Charged Pressure (kgf/cm2) 15 Mounting Ceiling Mount Type Operating Temperature Range ° (176) (C) Automatically at 57,68,93,107 &1430C Available in MAP 50/ MAP 90 Effective against A, B, C & Electrically started fires. Application: Class A Fire: Wood, Textiles, Paper, Clothes, Cotton Mill, Jute Mill etc Class B Fire: Petroleum, Oil, Paint, Varnish, Solvent, Aviation Fuel, Flammable and Volatile Liquids etc. Class C Fire: Flammable Gasses, Industrial Gasses etc. As well as Electrically Started Fires.
Technical Specification Capacity (Kg) 2,4 & 9 Working Pressure at (kgf/cm2) 15 Testing Pressure 32 Range of Discharge (Mtrs.) More than 2 Duration of Discharge (Sec.) More than 13 Operating Value Squeeze Grip Type with Nozzle Application: Class A Fire : Wood, Textiles, Paper, Clothes, Cotton Mill, Jute Mill etc. Class B Fire : Petroleum, Oil, Paint, Varnish, Solvent, Aviation Fuel, Flammable and Volatile Liquids etc. Class C Fire : Flammable Gasses, Industrial Gasses etc. As well as Electrically Started Fires.
Technical Specification Capacity (Kg) 1, 2, 4, 6 & 9 Chemical Charge Wet Chemical Working Temperature + 50 C to +550 C Cylinder testing Pressure 35 Bar Service Pressure 15 Bar Filling Tolerance 0, (-)5% by volume Minimum Effective Discharge Time 8 Seconds (Minimum) Discharge Quality More than 90% Application: Class A Fire : Wood, Textiles, Paper, Clothes, Cotton Mill, Jute Mill etc Class K Fire : Cooking Oil, Vegetable / Animal Oil and Fat Fire.
Technical Specification Capacity (Kg/Ltr) 4, 6 & 9 Extinguishing Media TEC Powder (Ternary Eutectic Chloride Powder) Minimum Effective Discharge(%) 95 Discharge Time More than 10 Sec. Testing Pressure (Kgf/cm2) 35 Charged Pressure (Kgf/cm2) 15 Effective Against Metal started fires. Expellant Pressurized with N2 Gas/ Gas Cartridge Application: Class D Fire: Effective on all types of Metal Fires. As well as Electrically Started Fires.
Trolley (Stored Pressure) by Mittal Trade Corp is the best in its category in Raipur. The quality of Trolley (Stored Pressure) is amazing. Trolley (Stored Pressure) by Mittal Trade Corp is among the top 10 in Telibandha, Raipur. Mittal Trade Corp offers great Trolley (Stored Pressure) deals in Raipur. Please share your contact details with us using the button below and we will contact you soon with best offers for Trolley (Stored Pressure).
Technical Specification Capacity (Kg) 9 Anti-Corrosive Inhibitor Epoxy Polyester Powder Coating Conforming IS Code 15683 Type of Extinguisher Constant Pressure Type of Extinguishing Media Soft Water Expellant Pressurized with N2 Gas/Gas Cartridge Minimum Effective Discharge (%) 95 Minimum Jet Length (mtrs.) More than 2 Discharge Time (Sec.) More than 13 Hydraulic Test Pressure (kgf/cm2) 35 Operating Position Upright Charged Pressure (kgf/cm2) 15 Operating Temperature Range ° (176) (C) (+)5 to (+)55 Operating Valve Squeeze Grip Type with Discharge Hose & Nozzle Application: Class A Fire: Wood, Textiles, Paper, Clothes, Cotton Mill, Jute Mill etc. Note: Do not use on energized Electrical Equipment fires.